The Multifunction Laser system provides the versatility to expand your practice according to your needs. This one system provides for multiple technologies including Intense Pulsed Light (IPL), Erbium YAG, Q-Switched Nd:YAG & KTP and 810nm Diode Laser.
With its multiple wavelengths, the system is easily upgradeable for future expansion. Having an expandable platform providing maximum flexibility can be paramount to the success of your practice.
Features & Benefits:
● Variable adapters provide quick, convenient spot size changes
● Ergonomic IPL handpiece with (4) wavelength filters
● Enhanced interfaces provides easy set up and operation
Clinical Uses:
Intense Pulsed Light (IPL)
● Active acne
● Uneven pigmentation
● Vascular lesions
● Hair removal
Erbium YAG
● Superficial skin resurfacing
● Fine lines & wrinkles
● Micro-laser peels
● Sun damaged skin
Q-Switched Nd:YAG & KTP
● Unwanted tattoos
● Pigmented lesions on skin types I-IV
810nm Diode Laser
● Unwanted body hair removal (arm, leg, face)
Specification:
Model | Medley |
Applied part | Handpiece |
Accuracy | ±10% |
Power supply | 230 VAC, 50 Hz, 2000 VA |
Dimensions (MM) | 495 (D)×525 (W)×1250 (H) |
Weight (KG) | 65 |
Size of screen | 8inch |
IPL Handpiece
Maximum Fluence | 35 J/cm² |
Wavelength | 450 ~ 1200 nm |
Spot Size | 40 × 8 mm ² |
Repetition Rate | 1 pulse every 3-seconds |
Aiming Beam | None |
Beam Delivery System | Direct |
Controls | Touch screen with LCD display, Footswitch |
Cooling | Self-Contained Closed Loop |
Er:YAG Handpiece
Energy | Up to 1000 mJ |
Maximum Power | 2.4 W |
Pulse Width | 500 μ s |
Wavelength | 2940 nm |
Beam Divergence | Collimated |
Spot Size | 1.5 ~ 6 mm (with zoom lens) step 0.5 |
NOHD | ≥180 m |
Repetition Rate | up to 10 pulse per second |
Controls | Touch screen with LCD display, Footswitch |
Cooling | Self-Contained Closed Loop |
Q-Switched Nd:YAG Handpiece
Energy | Up to 1000 mJ |
Wavelength | 1064 nm and 532 nm |
Spot Size | 1.5 ~ 4 mm (with zoom lens) |
Pulse Width | 200 μs |
Repetition Rate | 1 ~ 5 Hz |
NOHD | ≥1000 m |
Aiming Beam | Diode (635 nm, 10 mW max.) |
Beam Delivery System | Direct |
Controls | Touchscreen display, Footswitch |
Cooling | Self-Contained Closed Loop |
810nm Diode Laser Handpiece
Wavelength | 810 nm + 10% |
Spot Size (mm) | 10 x 14 |
Repetition rate | 1 - 10 Hz |
Fluence | 1 - 100 J/cm² |
NOHD | ≥ 30.1 m |
Pulse width | Auto, 30 ms, 100 ms, 200 ms, 400 ms |
Accuracy | ±10% |
Cooling method | Closed circulating water cooling |
Cooling temperature | 0 - 5 ℃ |
The Multifunction Laser system provides the versatility to expand your practice according to your needs. This one system provides for multiple technologies including Intense Pulsed Light (IPL), Erbium YAG, Q-Switched Nd:YAG & KTP and 810nm Diode Laser.
With its multiple wavelengths, the system is easily upgradeable for future expansion. Having an expandable platform providing maximum flexibility can be paramount to the success of your practice.
Features & Benefits:
● Variable adapters provide quick, convenient spot size changes
● Ergonomic IPL handpiece with (4) wavelength filters
● Enhanced interfaces provides easy set up and operation
Clinical Uses:
Intense Pulsed Light (IPL)
● Active acne
● Uneven pigmentation
● Vascular lesions
● Hair removal
Erbium YAG
● Superficial skin resurfacing
● Fine lines & wrinkles
● Micro-laser peels
● Sun damaged skin
Q-Switched Nd:YAG & KTP
● Unwanted tattoos
● Pigmented lesions on skin types I-IV
810nm Diode Laser
● Unwanted body hair removal (arm, leg, face)
Specification:
Model | Medley |
Applied part | Handpiece |
Accuracy | ±10% |
Power supply | 230 VAC, 50 Hz, 2000 VA |
Dimensions (MM) | 495 (D)×525 (W)×1250 (H) |
Weight (KG) | 65 |
Size of screen | 8inch |
IPL Handpiece
Maximum Fluence | 35 J/cm² |
Wavelength | 450 ~ 1200 nm |
Spot Size | 40 × 8 mm ² |
Repetition Rate | 1 pulse every 3-seconds |
Aiming Beam | None |
Beam Delivery System | Direct |
Controls | Touch screen with LCD display, Footswitch |
Cooling | Self-Contained Closed Loop |
Er:YAG Handpiece
Energy | Up to 1000 mJ |
Maximum Power | 2.4 W |
Pulse Width | 500 μ s |
Wavelength | 2940 nm |
Beam Divergence | Collimated |
Spot Size | 1.5 ~ 6 mm (with zoom lens) step 0.5 |
NOHD | ≥180 m |
Repetition Rate | up to 10 pulse per second |
Controls | Touch screen with LCD display, Footswitch |
Cooling | Self-Contained Closed Loop |
Q-Switched Nd:YAG Handpiece
Energy | Up to 1000 mJ |
Wavelength | 1064 nm and 532 nm |
Spot Size | 1.5 ~ 4 mm (with zoom lens) |
Pulse Width | 200 μs |
Repetition Rate | 1 ~ 5 Hz |
NOHD | ≥1000 m |
Aiming Beam | Diode (635 nm, 10 mW max.) |
Beam Delivery System | Direct |
Controls | Touchscreen display, Footswitch |
Cooling | Self-Contained Closed Loop |
810nm Diode Laser Handpiece
Wavelength | 810 nm + 10% |
Spot Size (mm) | 10 x 14 |
Repetition rate | 1 - 10 Hz |
Fluence | 1 - 100 J/cm² |
NOHD | ≥ 30.1 m |
Pulse width | Auto, 30 ms, 100 ms, 200 ms, 400 ms |
Accuracy | ±10% |
Cooling method | Closed circulating water cooling |